Prepared for
Shark Bay Resources Pty Ltd
Useless Loop · Heirisson Prong · Shark Bay, Western Australia
Project
Bitterns Recycling — Field Piping Installation
SOW 7.8 — PROVIDE PRIOR TO MOBILISATION

Hydrocarbon, Contamination
& Waste Control

Document numberDTL-PRJ0072-ENV-001
RevisionA — Issued for Approval
Date16 July 2026
AttentionMr John Stephens — Principal Representative
Scope of work23092-SOW-024rD §7.8
Submitted underSOW 7.8 — spill & contamination control, for SBR approval prior to site mobilisation
DTL (WA) Pty Ltd · 2/28 Horus Bend, Bibra Lake WA 6163 · ABN 45 677 646 454 · Commercial-in-Confidence
DTL (WA) Pty Ltd · Commercial-in-ConfidenceContract SBS10627 · PO 182113Page 1 of 6
Hydrocarbon, Contamination & Waste ControlBitterns Recycling Project — Field Piping Installation
DTL-PRJ0072-ENV-001
Rev A

§Document control

RevDateDescriptionByChkApp
A16 Jul 2026Issued to SBR for approval prior to mobilisationSHTK 
DRAFT for HSE review & SBR approval. SOW 7.8 requires DTL’s spill and contamination procedures to be provided to SBR for approval prior to site mobilisation. Site-specific details (bunding volumes, designated refuelling areas, SBR emergency contacts) to be confirmed on site walk / kick-off.

Approval

PREPARED — DTL
Sean Heron
Project Manager · Date
APPROVED — SBR
Principal Representative · Date
DTL (WA) Pty Ltd · Commercial-in-ConfidenceContract SBS10627 · PO 182113Page 2 of 6
Hydrocarbon, Contamination & Waste ControlBitterns Recycling Project — Field Piping Installation
DTL-PRJ0072-ENV-001
Rev A

1Purpose & the environment

Why this matters here. The Works are adjacent to SBR’s crystalliser ponds — a highly sensitive salt-production environment. A hydrocarbon spill or wind-blown contamination reaching the ponds could damage product and the environment. Strict prevention, containment and clean-up controls apply.

This procedure describes DTL’s methods for managing, storing, handling, preventing, containing and cleaning up hydrocarbon spills and other contamination, and for managing waste so there is no risk of contamination of the pond areas (SOW 7.8).

2Prevention

DTL (WA) Pty Ltd · Commercial-in-ConfidenceContract SBS10627 · PO 182113Page 3 of 6
Hydrocarbon, Contamination & Waste ControlBitterns Recycling Project — Field Piping Installation
DTL-PRJ0072-ENV-001
Rev A

3Spill response

  1. Stop the source — shut off / upright / plug where safe to do so.
  2. Contain — deploy spill-kit booms/pads to stop spread, especially any path toward drains or the ponds.
  3. Notifyreport to the SBR site representative immediately, no matter how small (SOW 7.8), and to the DTL Supervisor.
  4. Recover — absorb and collect contaminated material into labelled waste containers.
  5. Clean up & dispose — remove contaminated soil; dispose lawfully; restock the spill kit.
  6. Record — raise an incident report (DTL-HSE-FRM-0001) and review controls.
Spill kits are maintained on site and on vehicles, checked and restocked; all personnel are briefed on their location and use at induction and toolbox talks.
DTL (WA) Pty Ltd · Commercial-in-ConfidenceContract SBS10627 · PO 182113Page 4 of 6
Hydrocarbon, Contamination & Waste ControlBitterns Recycling Project — Field Piping Installation
DTL-PRJ0072-ENV-001
Rev A

4Waste & wind-blown contamination

5Roles & supporting documents

Doc No.Document
DTL-HSE-PRO-0018Hazardous Chemicals Procedure
DTL-HSE-PRO-0023Waste Management Procedure
DTL-HSE-REG-0001Chemical Register (incl. SDS)
DTL-HSE-FRM-0001Incident Report